| General system data |
| Switch type |
Interlock device with guard interlocking in accordance with EN 1088 |
| Service life (TM ) in accordance with EN ISO 13849-1 |
20 years |
| Number of cycles until 10 % of the components have a failure to danger (B10d) |
5,000,000 |
| Locking type |
Mechanical |
L100-P3C3-M20-SLM24
L100-P4C3-M20-SLM24 |
| Electromagnetic |
L100-P3C3-M20-MLM24 |
| Locking actuation |
Spring |
L100-P3C3-M20-SLM24
L100-P4C3-M20-SLM24 |
| Magnet |
L100-P3C3-M20-MLM24 |
| Temperature range, operation |
-25...+60 °C |
| Dirt levels, external, in accordance with EN 60947-1 |
3 |
| Housing material |
Fiberglass-reinforced, thermo-plastic plastic, self-extinguishing |
| Actuator, external |
AC-AHxx, series, straight, angled, resilient, alignable |
| Dimensions |
See dimensional drawing |
| Protection rating |
IP 66 |
| Contact protection |
Protective insulation O |
| Approach actuation directions |
1 x above, 4 x side (90°) |
| Mechanical life time in accordance with IEC 6047-5-1 |
0.8x10 6 actuation cycles |
| Actuation frequency in accordance with IEC 6047-5-1 |
Max. 600 activations an hour |
| Approach speed |
Max. 0.5 m/s |
| Actuation force (extraction) |
30 N |
| Recoil tolerance |
4.5 mm |
| Interlocking force |
Max. 1100 N |
| Contact allocation |
Magnet: 1 NC + 1 NO |
L100-P3C3-M20-SLM24
L100‑P3C3‑M20-MLM24 |
Magnet: 2 NC  |
L100-P4C3-M20-SLM24 |
Actuator: 1 NC  |
L100-P3C3-M20-SLM24
L100‑P3C3‑M20-MLM24
L100-P4C3-M20-SLM24 |
| Switching principle |
Creep contact |
| Contact opening |
Force-fit |
| Contact material |
Silver alloy |
| Magnet operating voltage and tolerance |
24 V DC (-10 % to +25 %) |
| Duty cycle |
100 % |
| Power consumption |
Average, 20 VA |
| Switch-on power limit, adjustable |
4-way |
| Usage category in accordance with EN 60947-5-1 |
AC 15: Ue / Ie: 250 V / 6 A, 400 V / 4 A, 500 V / 1 A
DC 13: Ue / Ie: 24 V / 6 A, 125 V / 1.1 A, 250 V / 0.4 A |
| Rated insulation voltage |
400 V AC |
| Conventional thermal current |
Max. 10 A |
| Short-circuit protection in accordance with IEC60269-1 |
Magnet |
24 V, 1.0 A, type aM |
| Safety circuit |
500 V, 10 A, type aM |
| Connection system |
Number of cable entries |
3 |
| Type of cable entries |
M20 x 1.5 |
| Cable cross-section (wire) |
1 x 0.34 mm² to 2 x 1.5 mm² |