COMPACTplus-b

Safety Light Curtains


COMPACTplus-b - Safety Light Curtains
CE TÜV UL listed IP 65

Point of operation guarding: Light Curtain with finger resolution Point of operation guarding: Light Curtain with hand resolution Danger zone guarding: Light Curtain Access guarding: Light Curtain

With special task requirements in material conveyance, the blanking of individual beams may be required in order to ensure an efficient, continuous process while simultaneously guaranteeing safety.

The COMPACTplus-b type 4 Safety Light Curtains in accordance with IEC/EN 61496 have been designed with these requirements in mind. They provide blanking functions for blanking any amount of beams and beam areas of varying sizes. Work pieces, for example, consequently pass through the protective field without interruption. By setting a reduced resolution, thin plates or tubes can also move through the protective field. COMPACTplus Safety Light Curtains and Multiple Light Beam Safety Devices can be equipped with various functions to optimally perform specific tasks with regard to higher functionality, more flexible integration and easier operability.

The COMPACTplus series have a start/restart interlock, contactor monitoring and additional functions that can be easily activated with switches. External additional modules are therefore no longer required. Specific settings are made with the diagnostics and parametering software, SafetyLab. COMPACTplus can be connected to both conventional safety modules and to open safety bus systems via various interfaces (transistor/relay output, AS-Interface Safety at Work , PROFIsafe). These safety sensors can therefore be flexibly integrated into existing automation environments.


Special features
  • Plug-in module with saved device parameters for fast device swap-out

  • M12 local connection socket for connecting local sensors and signal devices


Important technical data, overview
Type in accordance with IEC/EN 61496 Type 4
SIL in accordance with IEC 61508 and
IEC/EN 62061
SIL 3
Performance Level (PL) in accordance with EN ISO 13849-1 PL e
Category in accordance with EN ISO 13849 and EN 954-1 4
Resolution 14 mm 30 mm 50 mm
Range 0...6 m 0...18 m 0...18 m
Protective field height (type-dependent) 150 ...3000 mm
Profile cross-section 52 mm x 55 mm
Safety-related switching outputs (OSSDs) 2 PNP transistor outputs, 2 relay outputs AS-i Safety interface PROFIsafe interface
Connection system Cable gland Hirschmann plug MIN-style plug M12 plug

Functions
Start/restart interlock (RES), selectable
Dynamic contactor monitoring (EDM), selectable
2 transmission channels, selectable
Fixed blanking can be taught in
Floating blanking can be taught in
Single-beam or 2-beam reduced resolution
Additional 2-channel blanking circuit

Functions extension with "SafetyLab" PC software (accessories)
Infrared interface for parametering and diagnostics
Teaching-in override function for floating blanking
Graphics-supported protective field editor
Reduced resolutions in protective field sub-areas
3-beam reduced resolution
Beam signals for position and height measuring