COMPACTplus/AS-i

Multiple Light Beam Safety Devices


COMPACTplus/AS-i - Multiple Light Beam Safety Devices
CE TÜV cUL US listed IP 65 AS-Interface - Safety at Work

Access guarding: Multiple Light Beam Safety Device

Special features
  • Type 4 Multiple Light Beam Safety Device in accordance with IEC/EN 61496-1/-2

  • Integrated AS-Interface, bus connection via the M12-AS-i Adapter for AS-i data transfer and separate 24 Volt power supply

  • Safe data transfer of the OSSD signals via AS-Interface

  • Device swap-out without PC via SERVICE function of the AS-i Safety Monitor

  • Direct connection of muting sensors, start/restart button or indicator directly on the device via sensor connection module

  • Muting restart function possible via AS-Interface by calling up AS-i-IC parameters

  • Additional diagnostics information via AS-Interface, e.g. muting sensors status, muting or weak signal display

Important technical data, overview
Type in accordance with IEC/EN 61496 4
SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 3
Performance Level (PL) in accordance with EN ISO 13849-1 e
Category in accordance with EN ISO 13849 4
Number of beams 2 3 4
Beam distance 500 mm 400 mm 300 mm
Range (type-dependent) Cxx0/y:
Cxx1/y:
0...18 m
6...70 m
Muting transceiver range (type-dependent) 0...6.5 m
Profile cross-section 52 mm x 55 mm
Safety-related switching output (OSSD) AS-i Safety Interface
Connection system M12 plug (AS-i Safety)
AS-i profile S-7.B.1, safe slave
Slave address 1...31, programmable (factory setting = 0)
Cycle time in accordance with AS-i specifications 5 ms
Current consumption from AS-i circuit 50 mA
Sensor response time 24 ms, 25 ms (muting transceiver)
Restart delay time 20...5000 ms, can be set with SafetyLab software,
presetting 100 ms (after protective field release)