COMPACT EX2

Multiple Light Beam Safety Devices


COMPACT EX2 - Multiple Light Beam Safety Devices
CE Ex protection

Access guarding: Multiple Light Beam Safety Device

Devices and protective systems must meet special requirements with use in explosion-risk areas. COMPACT EX2 devices with the "non-sparking" ignition protection type and special precautions on the transmitter and receiver housing are available in different models for these applications.

COMPACT EX2 devices are suited for being used up to Ex zone 2 (gases) and Ex zone 22 (flammable, non-conductive dusts). They are especially impressive due to their high interference immunity and availability. In addition to the requirements of machine safety, COMPACT EX2 also satisfies the provisions of ATEX Directive 94/9/EC.

Reinforced connecting front screens ensure that the housing remains sealed with mechanical influences, e.g. an impact or blow of some kind. Metal bushings enclose the cables suitable for explosion-risk areas, which are to be provided by the customer. COMPACT EX2 can be used in industrial applications, however it cannot be used in pits. The device complies as an electrical piece of apparatus of EX device group II, EX category 3.


Special features
  • Type 4, suitable for safety category 4

  • Complies with ATEX Directive 94/9/EC (ATEX Directive)

  • Fault-free operation of adjacent devices with selection of different transmission channels

  • Maintenance-free with safety transistor outputs (OSSDs)

  • Ignition protection type "nA" non-sparking

  • Integrated auto-diagnostics system

  • Function extensions with MSI Safety Relays are possible

Important technical data, overview
Type in accordance with IEC/EN 61496 Type 4
SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 SIL 3
Performance Level (PL) in accordance with EN ISO 13849-1 PL e
Category in accordance with EN ISO 13849 4
Number of beams 2 3
Beam distance 500 mm 400 mm
Range 18 m
SingleScan response time 5 ms
Profile cross-section 52 mm x 55 mm
Safety-related switching outputs (OSSDs) 2 PNP transistor outputs
Connection system Cable gland
Ex device group II
Ex device category 3
Temperature class T4
Permissible ignition temperature T > 135 °C
Ignition protection type "nA" non-sparking

Functions
Start/restart interlock (RES), selectable
Dynamic contactor monitoring (EDM), selectable
2 transmission channels, selectable
LED display, 7-segment display