| General system data |
| Type in accordance with IEC/EN 61496 |
Type 2 in combination with a Safety Interface or a Test Monitoring Unit |
| Service life (T M ) in accordance with EN ISO 13849-1 |
20 years |
| Category in accordance with EN ISO 13849 and EN 954-1 |
2 |
| Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 |
301 years |
| Operating range |
0...6 m |
| Response time |
5 ms |
| Operating voltage UB |
24 V DC ± 15% |
| Safety class |
II |
| Protection rating |
IP 67 |
| Temperature range, operation |
-20...+60 °C |
| Temperature range, storage |
-30...+70 °C |
| Dimensions (WxHxD) |
27 mm x 14.6 mm x 52 mm |
| Housing |
Metal/stainless steel V2A (1.4305), polycarbonate rear panel |
| Weight (transmitter and receiver) |
40 g (plug variant), 100 g (cable variant) |
| Transmitter |
| Current consumption |
20 mA |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Light source |
Infrared light |
| Wavelength |
880 nm |
| Activation input for testing and series connection |
24 V DC active ≥ 8 V inactive ≤ 2 V |
| Connection system |
Cable, 2.5 m
M8 round pin plug, 3-pin |
| Receiver |
| Current consumption |
15 mA without external load |
| Switching output |
pnp transistor output |
| Switching voltage high active |
Min. Uv – 2 V |
| Switching voltage low |
max. 2 V |
| Output current |
max. 100 mA |
| Connection system |
Cable, 2.5 m
M8 round pin plug, 3-pin |