COMPACT

Technical Data

Safety Light Curtain / Multiple Light Beam Safety Device
COMPACT
Safety performance Type 4 according to EN 61496-1, -2 and/or IEC 61496 -1,-2
(self-monitoring)
Protected height 150...1800 mm for series C14 and C30
(1950, 2100, 2250 mm on request)
450...3000 mm for series C50
750...3000 mm for series C90
Protected width, Range 0,3...6 m for series C14
0,8...18 m for series C30, C50, C90, Cxx0/y
6,0...60 m for series Cxx1/y
Resolution (object sensitivity) 14 mm, 30 mm, 50 mm, 90 mm and/or
whole person with 2, 3 or 4 beams
Response time (from interrupting the sensing field to switching off the OSSDs) Response time increases in proportion to number of beams
series C14: 7...39 ms (d-scan 10...78 ms)
series C30: 7...20 ms (d-scan 10...39 ms)
series C50:<17 ms (d-scan 33 ms)
series C90: <13 ms (d-scan 20 ms)
Restart time (after release of sensing field to switching on OSSDs) If interruption of sensing field is very short, OSSDs remain switched off for at least 100 ms.
Enclosure rating IP 65
Ambient temperature 0...+55 °C
Supply voltage 24 V DC ±20 %
External supply unit with safe disconnecting function from the supply and 20 ms mains failure bridging
Current consumption Transmitter: 75 mA
Receiver: 180 mA (without load)
Safety outputs (OSSDs) 2 fail-safe pnp-outputs with cross circuit monitoring,
UONmin = Usupply - 2,7 V
Surge current (100ms) = 0,4A
Permanent current at 35 °C = 0,3A
Permanent current at 55 °C = 0,22A
Max. capacitive load per output = 0,3 mF
(0,1 mF for channel 2)
Contamination and fault output pnp output short circuit proof, 70 mA max
Interface for safety and diagnosis RS-485, 57,6 kBaud max.
Test input transmitter Closed circuit operation, min. lenght of opening 50 ms
Electrical Connection Via PG 13.5 and/or PG 9, screw terminals and plug-in connection device, alternatively via plug according to DIN 43651 or Brad-Harrison-Min.
Connection cable Transmitter: 7pol, max 1,0 mm²
Receiver: 7pol, max 1,0 mm²
(îf necessary shielded)
Lenght of circuit max 100 m at 1,0 mm²
Type of operation Protective operation without restart interlock
Synchronization Transmitter/receiver Optical synchronization, 2 transmission channels can be selected
Suppression of infrared interfering light 2 methods can be selected
Standard: high suppression
d-scan: very high suppression (response time increases according to measurement table)
Dimensions Cross section 55 x 52 mm
length depending on protected height 234...3084 mm
Air humidity 15 ... 95 %
Storage temperature -25 ... +70 °C